品質 OLYMPUS 修理用電子大腸内視鏡 CF-H180AL 工場

OLYMPUS 修理用電子大腸内視鏡 CF-H180AL

OLYMPUS CF-H180AL Electronic Colonoscope For Repair ► Brief Description Inspection Results: 1. The image is dark, and the CCD is aged. 2. One branch of the light beam is disconnected. 3. The insertion tube is aged and wrinkled. 4. The lower angle is malfunctioning, the other angles are tight, and the snake bone is deformed. 5. The light guide tube is slightly wrinkled. Solution: Repair and Replacement: CCD, light bundle, insertion tube, biopsy tube, snake bone, steel wire,

品質 GE 4D3C-L 4D コンベックス超音波プローブ 修理用 工場

GE 4D3C-L 4D コンベックス超音波プローブ 修理用

GE 4D3C-L 4D Convex Transducer For Repair ► Brief Description Fault: 1.Probe dome abrasion & leakage, 2. Dome tube damaged, 3. 4D function not work, 4. Electric motor damaged. Solution:Replace the dome, dome tube; repair electric motor. ►Problem & Solutoin BrandGEModel4D3C-LFault1.Probe dome abrasion & leakage, 2. Dome tube damaged, 3. 4D function not work, 4. Electric motor damaged.SolutionReplace the dome, dome tube; repair electric motor ►Common issues with 4D3C-L 4D

品質 GE 4C-RS 腹部プローブ修理用 工場

GE 4C-RS 腹部プローブ修理用

GE 4C-RS abdominal probe for repair ► Brief Description Fault: Lens broken, cable broken, crystal bad. Solution: Replace probe head, repair cable. ►Problem & Solutoin Bran GE Model 4C-RS Fault Lens broken, cable broken, crystal bad Solution Replace probe head, repair cable ► Common issues with 4C-RS Probe Image dropouts / Black lines Acoustic lens damage Cable damage Connector damage Oil leakage If your instrument has any of the above problems or others, please feel free to

品質 S5-2 心臓探査機 修理 工場

S5-2 心臓探査機 修理

S5-2 Cardiac probe for repair Fault: Lens problem, cable broken, without strain relief. Solution: Replace probe lens, repair cable, replace strain relief. ►Problem & Solutoin Model S5-2 Fault Lens problem, cable broken, without strain relief Solution Replace probe lens, repair cable, replace strain relief ► Common issues with S5-2 Cardiac probe Poor or blurry images Constant noise or static Color streaking or intermittent artifacts Cracked or dried-out lens Cable or strain

品質 Olympus LTF-160 胸腔鏡修理用 工場

Olympus LTF-160 胸腔鏡修理用

Olympus LTF-160 thoracoscope for repair ► Brief Description Fault: 1.with image, but big risk for CCD after leakage. 2. Light bundle broken completely. 3. Insert tube with little scratch. 4. Biopsy tube abrasion and leakage. 5. Wires and helix tube abrasion. 6. Grip broken, leakage. 7. All the buttons failure. 8. Rubber leakage. 9. the whole scope leakage. Solution: Replace CCD,light bundle, biopsy tube, wires,helix tube,grip and rubber, repair all the buttons. ►Problem &

品質 ソノスケープ EG-500 電子胃鏡 修理のため 工場

ソノスケープ EG-500 電子胃鏡 修理のため

SonoScape EG-500 Electronic Gastroscopy For Repair ► Brief Description Inspection Results: 1. No image display, CMOS water ingress fault; 2. 20% of the light bundle is broken; 3. There are bite marks on the insertion tube in multiple places; 4. The biopsy tube is worn out and not smooth; 5. The angle is seriously insufficient and tight, with wear on the snake bone, steel wire, and helix tube; 6. The light guide tube has dents; 7. The handle shell is cracked and has severe

品質 Olympus Flexible Endoscope Air & Water Tube A/W Transparent Tube 工場

Olympus Flexible Endoscope Air & Water Tube A/W Transparent Tube

Olympus/ Pentax/ Fuji A/W Tube ► Brief Description The "air/water channel" is a critical part of a flexible endoscope's function. The tube you are referring to is most commonly known as the Air/Water Valve Tube or A/W Tube . It's a small, transparent, and highly flexible tube that connects the air and water valves on the control body of the endoscope to the internal channel that runs the length of the insertion tube. ► 1. Primary Purpose and Function This single, transparent

品質 オリンパス TJF-160VR用の柔軟なエンドスコップボディカバー 工場

オリンパス TJF-160VR用の柔軟なエンドスコップボディカバー

Flexible Endoscope body cover for Olympus TJF-160VR ► Brief Description The body cover of the Olympus TJF-160VR is a critical component designed to ensure ergonomic comfort, durability, and protection for the endoscope's operational controls during clinical procedures. It is engineered to withstand frequent disinfection cycles and mechanical stress while maintaining optimal functionality. ► Features Ergonomic Design​ Protection and Durability Operational Efficiency Hygiene

品質 MAJ-210 OLYMPUS 柔らかいエンドスコープ用のバイオプシーバルブ 工場

MAJ-210 OLYMPUS 柔らかいエンドスコープ用のバイオプシーバルブ

MAJ-210 OLYMPUS BIOPSY VALVE FOR FLEXIBLE ENDOSCOPE ► Brief Description The Olympus MAJ-210 is a single-use, sterile biopsy valve designed for use with a range of Olympus endoscopes. It's a critical accessory for various endoscopic procedures. ► Features Instrument Access: Its primary function is to provide a sealed entry point for inserting and exchanging endoscopic instruments (such as biopsy forceps, snares, cytology brushes, or other therapeutic tools) through the