品質 MAJ-210 OLYMPUS 柔らかいエンドスコープ用のバイオプシーバルブ 工場

MAJ-210 OLYMPUS 柔らかいエンドスコープ用のバイオプシーバルブ

MAJ-210 OLYMPUS BIOPSY VALVE FOR FLEXIBLE ENDOSCOPE ► Brief Description The Olympus MAJ-210 is a single-use, sterile biopsy valve designed for use with a range of Olympus endoscopes. It's a critical accessory for various endoscopic procedures. ► Features Instrument Access: Its primary function is to provide a sealed entry point for inserting and exchanging endoscopic instruments (such as biopsy forceps, snares, cytology brushes, or other therapeutic tools) through the

品質 オリンパス Bw-20t 柔軟性のある内視鏡のための掃除ブラシ 工場

オリンパス Bw-20t 柔軟性のある内視鏡のための掃除ブラシ

Olympus Bw-20t Cleaning Brush ► Brief Description The Olympus BW-20T is a widely used and essential reusable cleaning brush specifically designed for the manual cleaning of the instrument channels of Olympus flexible endoscopes. This brush plays a crucial role in the reprocessing of endoscopes to ensure patient safety and effective device function. ► Features Mechanical Cleaning of Instrument Channels: The primary function of the BW-20T is to mechanically scrub and remove

品質 PENTAX EC-3890LK コロノスコップのための柔軟性のあるエンドスコップ部品 CCDドライバボード 工場

PENTAX EC-3890LK コロノスコップのための柔軟性のあるエンドスコップ部品 CCDドライバボード

CCD Driver Board For PENTAX EC-3890LK Colonoscope ► Brief Description The CCD Driver Board for the PENTAX EC-3890LK is a critical internal electronic component located within the video colonoscope. Its primary role is to drive the Charge-Coupled Device (CCD) image sensor located at the distal tip of the endoscope. It manages the precise timing signals required to capture high-resolution medical images and prepares the raw video data for transmission back to the main PENTAX

品質 柔軟性のある内視鏡部品 ペンタックス EG-27i10 胃視鏡 PCBボード CCDドライブボード 工場

柔軟性のある内視鏡部品 ペンタックス EG-27i10 胃視鏡 PCBボード CCDドライブボード

Bending Rubber For Olympus CF-H290I Colonoscope ► Brief Description The CCD Driver Board for PENTAX EG-27i10 is a critical, high-precision electronic subassembly located within the connector or control body of the PENTAX i10-series video gastroscope. Acting as the primary hardware interface between the endoscope’s distal end Megapixel CCD (Charge-Coupled Device) sensor and the external video processor (such as the PENTAX EPK-i series), this board manages low-level timing,

品質 オリンパス ENF-GP 繊維鼻喉鏡 修理用 工場

オリンパス ENF-GP 繊維鼻喉鏡 修理用

Olympus ENF-GP fiber nasopharyngeal laryngoscope for repair ► Brief Description Fault: 1. Image with black point and image bundle broken 2. Light bundle aged 3. Insert tube aging and wrinkle 4. Bending section deformation 5. Angle with not enough 6. Rubber abrasion Solution: Replace image bundle; light bundle; insert tube; wires; helix tube; bending section; rubber ►Problem & Solutoin Brand Olympus Model ENF-GP Fault 1. Image with black point and image bundle broken 2. Light

品質 OLYMPUS 電子十二指腸鏡 修理用 TJF-Q180V 工場

OLYMPUS 電子十二指腸鏡 修理用 TJF-Q180V

OLYMPUS TJF-Q180V Electronic Duodenoscope For Repair ► Brief Description Inspection Results: 1. Image display is available; 2. The light bundle brightness is acceptable; 3. The insertion tube is worn; 4. The light guide tube is worn; 5. The angle is insufficient, the snake bone, steel wire and helix tube are worn; 6. The forceps elevator handle is damaged; 7. The handle shell is severely cracked. Solution: Replacement: Insertion tube, handle shell, light guide tube, snake

品質 1898200T M4 直熱マイクロブレッダーとハンドピースの修理 工場

1898200T M4 直熱マイクロブレッダーとハンドピースの修理

1898200T M4 Straightshot Microdebrider and Handpiece for repair ► Brief Description Fault: 1) The bearing is corroded and the seal is broken. 2) Motor stuck, inside is full of disinfection residue, motor corrosion. 3) The rotation direction of the knife head is stuck. 4) Handle paint off, internal corrosion.. Solution: Exchange the whole handpiece except cable. ►Problem & Solutoin Model 1898200T Fault 1) The bearing is corroded and the seal is broken. 2) Motor stuck, inside

品質 GE RIC6-12-D 内腔探査機 修理 工場

GE RIC6-12-D 内腔探査機 修理

GE RIC6-12-D endocavity probe for repair ► Brief Description Fault: Lens problem. Solution: Replace lens,Clean cable. ►Problem & Solutoin Brand GE Model RIC6-12-D Fault Lens problem Solution Replace lens,Clean cable ► Common issues with RIC6-12-D Probe Dome Damage and Fluid Leaks Image Dropouts (Dead Elements) Cable and Connector Issues Motor/Steering Failure (for 4D functionality) If your instrument has any of the above problems or others, please feel free to contact us for

品質 オリンパス TJF-Q180V 十二指腸鏡 修理用 工場

オリンパス TJF-Q180V 十二指腸鏡 修理用

OLYMPUS TJF-Q180V DUODENOSCOPE FOR REPAIR ► Brief Description Fault: 1. Image ok; 2. Light bundlestill ok; 3. Insert tubestill ok; 4. Biopsy tubewear; 5. Bendingsection, wires and helix tube wear; 6. Knob leakage. Solution: Suggest toreplace biopsy tube, bending section, wires, helix tube, knob and rubber. (Nowarranty for CCD). ►Problem & Solutoin Brand OLYMPUS Model TJF-Q180V Fault 1. Image ok; 2. Light bundlestill ok; 3. Insert tubestill ok; 4. Biopsy tubewear; 5.