品質 防水キャップ MH-553 オリンパス 柔軟なビデオ内視鏡用 工場

防水キャップ MH-553 オリンパス 柔軟なビデオ内視鏡用

Water-Resistant Cap MH-553 For Olympus Flexible Video Endoscopes ► Brief Description The Olympus MH-553 is a critical accessory used in medical endoscopy, specifically designed as a Water-Resistant Cap (also known as a Soaking Cap or Leak Test Cap). Its primary purpose is to protect the sensitive electrical connectors of a flexible endoscope during the cleaning, disinfection, and sterilization processes. ► Features Water Ingress Protection Leakage Testing Support Reprocessing

品質 PENTAX メディカル EPK-i7000 ビデオプロセッサ 修理 工場

PENTAX メディカル EPK-i7000 ビデオプロセッサ 修理

PENTAX Medical EPK-i7000 Video Processor For Repair ► Brief Description Brand: PENTAX (PENTAX Endoscope Processor) Model: EPK-i7000 Serial Number: AC*** Fault: It cannot recognize the endoscope and reports an error. Solution: Repair the system board. Repair Time: 3-5 working days. Warranty Period: Six months. ►Problem & Solution Brand PENTAX Model EPK-i7000 Product Processor Fault It cannot recognize the endoscope and reports an error. Solution Repair the system board. ►

品質 Eus エンドスコップ オリンパス吸管のための柔軟性のある内視鏡部品 工場

Eus エンドスコップ オリンパス吸管のための柔軟性のある内視鏡部品

Detail olympus suction valve maj-1443 for eus endoscopes Olympus SUCTION VALVE MAJ-1443 Brand: Olympus Series: SUCTION VALVE Model:MAJ-1443 Description .Suction Valve, Autoclavable, Non-Sterile, Reusable, For EUS Endoscopes . Helps prevent backflow . Reusable CareUtech is the global provider of medical equipment and medical equipment repair service, as well as offering spare parts. We focus on repair and repair training for monitor, Flexible & Rigid Endoscope, ultrasound,

品質 オリンパス柔軟性エンドスコップ用の空気水バルブ MAJ-1444 工場

オリンパス柔軟性エンドスコップ用の空気水バルブ MAJ-1444

Air Water Valve MAJ-1444 ► Brief Description The Olympus MAJ-1444 is an Air/Water Valve primarily used with Olympus Ultrasonic Endoscopes (EUS - Endoscopic Ultrasound). This valve plays a crucial role during endoscopy procedures, enabling the controlled delivery of air and water to the endoscope's distal tip. ► Features Air Insufflation Water Jet/Washing Cleaning the Objective Lens Washing the Examination Area Balloon Inflation (for EUS probes) One-Way Valve Functionality

品質 オリンパス A70940A 修理用オートクレーブ対応関節鏡 工場

オリンパス A70940A 修理用オートクレーブ対応関節鏡

Olympus A70940A Autoclavable Arthroscope for repair ► Brief Description Fault: 1. Image blur, black dots and dark. 2. Fiber not light enough. 3. Rod lens broken. 4. Objective lens broken and dirty. Solution: 1. Replace rod lens. 2. Replace inner tube. 3. Replace outer tube. 4. Replace objective lens group. 5. Clean the eyepiece. 6. Replace fiber. 7. Clean and install the optical path, check the image. 8. Seal with endoscope and test. ►Problem & Solutoin Brand Olympus Model

品質 オリンパス A4674A 修理用オートクレーブ対応子宮鏡 工場

オリンパス A4674A 修理用オートクレーブ対応子宮鏡

Olympus A4674A Autoclavable Hysteroscope for repair ► Brief Description Fault: 1. Image blur and black shadow. 2. Rod lens broken. 3. Outer tube bending and transformation. Solution: 1. Replace rod lens. 2. Replace inner tube. 3. Replace outer tube. 4. Replace objective lens group. 5. Clean the eyepiece. 6. Replace fiber. 7. Clean and install the optical path, check the image. 8. Seal with endoscope and test. ►Problem & Solutoin Brand Olympus Model A4674A Fault 1. Image blur

品質 Karl Storz 27005BA Cystoscope for repair 工場

Karl Storz 27005BA Cystoscope for repair

Karl Storz 27005BA Cystoscope for repair ► Brief Description Fault: 1. No image. 2. Fiber abrasion. 3. Rod lens broken and cracked. 4. Objective lens broken and dirty. 5. Eyepiece cover broken. Solution: 1. Replace rod lens. 2. Replace inner tube. 3. Replace outer tube. 4. Replace objective lens group. 5. Clean the eyepiece. 6. Replace fiber. 7. Replace eyepiece cover. 8. Clean and install the optical path, check the image. 9. Seal with endoscope and test. ►Problem & Solutoin

品質 オリンパス CF-H190L コロノスコップの修理用ケース 工場

オリンパス CF-H190L コロノスコップの修理用ケース

Olympus CF-H190L Colonoscope for repair,SN:261****. Fault:Light bundle broken,biopsy tube worn,water air tube leakage,bending section deformation,wire helix tube worn. Solution:Replace the bending section,wire,helix tube,air tube and rubber.PS:Warranty for replace parts only. Repair time:7 working days. Repair price:$****. Warranty:90 days. Guangzhou Care techonoly Co., Ltd. is a company dedicated to the supply of medical equipment maintenance tools, maintenance accessories,

品質 医療機器の修理 GE RIC5-9-D 超音波探査機の修理用ケース 工場

医療機器の修理 GE RIC5-9-D 超音波探査機の修理用ケース

GE RIC5-9-D Probe Fault: Dome loose, straight relief tiny broken, with error on machine. Solution: Replace dome and oiling. Repair cost : $***. Common Issues with the GE RIC5-9-D Ultrasound Probe: Image Artifacts/Dropouts: These can manifest as lines, shadowing, or a complete loss of image in certain areas. Common causes include: Crystal Damage: Piezoelectric crystals within the transducer array can become damaged due to physical impact, overheating, or degradation over time.